The normal operation of air source system of concrete mixing station determines whether the whole concrete mixing station can work normally. So how to solve the air source failure of concrete mixing station? What are the air source failures of concrete mixing station? Today, the great wall of Zhengzhou will give you an analysis. The air supply system of concrete mixing station will have problems in the following aspects under normal circumstances:
1. The check valve is damaged, the piston ring is worn seriously, the intake valve piece is damaged and the air filter is blocked.
2. Pressure relief valve failure, pressure adjustment is not high, or pressure rise slowly.
3. Pipeline failure, pipeline joint leakage, hose rupture, condensation water accumulation.
4. Compressed air handling unit (TRIAD) failure, oil-water separator fault, pressure regulating valve and oil mist device failure, so we know what are prone to failure, how should we solve the air source failure of concrete mixing plant?
First of all, we have to wait for more than ten seconds after the automatic shutdown of the air compressor, turn off the power supply, and turn the large belt pulley manually. If it can be turned around easily, it means that the check valve is not damaged; on the contrary, the check valve has Damage; in addition, you can also judge from the exhaust port under the automatic pressure switch. Under normal circumstances, our air compressor will stop exhausting after more than ten seconds after automatic shutdown. If the exhaust is stopped until the air compressor starts again, it indicates that the check valve has been damaged and must be replaced at this time. In addition, we should check whether the air flow rate of our air inlet is lower than the mist flow rate, whether there is air leakage, whether the oil volume regulating needle valve is blocked, etc.; if the water is deposited at the bottom of the oil cup, the concrete mixing station should remove it in time; when the sealing ring is damaged, it should be replaced in time.
As long as we solve the problem of air source failure of concrete mixing station above, we can normally ensure the normal operation of our concrete mixing station. The above is our Zhengzhou Great Wall Co., Ltd. summed up on the concrete mixing plant air source failure of some treatment methods, for your reference only, this article without the consent of the author, no reprint!